Product Performance

Load Bearing Expand to view deflection table
 Component Load Test Data and Material
Main Tee Length Allowable Load per ASTM C635
Hanger Spacing
4' 5' 6'
Cross Tee Length 2' 4'
1232.01G90 24" 40.5▲
1234.01G90 48" 17.0
230.XXZ.01 144" HD 8.9 5.6
640.00CG90 144" HD
663.00CG90 48" 17.0

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.

 Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
230.XXZ.01 1234.01G90
1' x 4' 67.6
2' x 2' 52.8
2' x 4' 76.0▲

▲ Limited by safety factor of 2.

Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations
This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures.
Environment Materials and Resources (MR)
-Waste Management Planning
-Interiors Life Cycle Impact Reduction
-Environmental Product Declarations
-Sourcing of Raw Materials
-Material Ingredients
-Waste Management
Indoor Environmental Quality (EQ)
-Low-Emitting Materials
-Interior Lighting
-Acoustic Performance
Back
 Component Load Test Data and Material
Main Tee Length Allowable Load per ASTM C635
Hanger Spacing
4' 5' 6'
Cross Tee Length 2' 4'
1232.01G90 24" 40.5▲
1234.01G90 48" 17.0
230.XXZ.01 144" HD 8.9 5.6
640.00CG90 144" HD
663.00CG90 48" 17.0

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.

 Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
230.XXZ.01 1234.01G90
1' x 4' 67.6
2' x 2' 52.8
2' x 4' 76.0▲

▲ Limited by safety factor of 2.

Back
Back

Accessories

148780_r1_ROC_GridDS_EPSFiles_SingleImages_G90

Compatible Tile Edge Types

1516-inch Edges

G90 Acoustical Grid Systems

Back

Resources

 

 

print pdf
icon
Rockfon Seismic Relief Brochure
Rockfon Seismic Relief Brochure

pdf
icon
Rockfon Seismic Relief Brochure FR
Rockfon Seismic Relief Brochure FR

pdf
icon
EPD Steel CISCA
EPD Steel CISCA

pdf
icon
Chicago Metallic® G90 Exposed Grid 15/16" System Datasheet
Chicago Metallic® G90 Exposed Grid 15/16" System Datasheet

pdf
icon
Chicago Metallic® G90 Exposed Grid 15/16" System Datasheet FR
Chicago Metallic® G90 Exposed Grid 15/16" System Datasheet FR

pdf
icon
Chicago Metallic® G90 Drywall Grid 1 3/8" System Datasheet
Chicago Metallic® G90 Drywall Grid 1 3/8" System Datasheet

pdf
icon
Chicago Metallic® G90 Drywall Grid 1 3/8" System Datasheet FR
Chicago Metallic® G90 Drywall Grid 1 3/8" System Datasheet FR

pdf
icon
Rockfon® Accessories Datasheets
Rockfon® Accessories Datasheets

pdf
icon
Rockfon® Accessories DataSheet FR
Rockfon® Accessories DataSheet FR

pdf
icon
Rockfon Using 12 Gauge Hanger Wire Installation Guide
Rockfon Using 12 Gauge Hanger Wire Installation Guide

pdf
icon
Rockfon Product Cleaning and Maintenance Tech Note
Rockfon Product Cleaning and Maintenance Tech Note

pdf
icon
Rockfon Product Cleaning & Maintenance Tech Note FR
Rockfon Product Cleaning & Maintenance Tech Note FR

pdf
icon
Chicago Metallic G90 Exterior Grade Drywall System Specification
Chicago Metallic G90 Exterior Grade Drywall System Specification

pdf
icon
Chicago Metallic G90 Exterior Grade Drywall System CDN Specification
Chicago Metallic G90 Exterior Grade Drywall System CDN Specification

pdf
icon
Chicago Metallic G90 Exterior Grade System CDN Specification
Chicago Metallic G90 Exterior Grade System CDN Specification

pdf
icon
Rockfon 40 Year Suspension System Warranty
Rockfon 40 Year Suspension System Warranty

pdf
Back